SUPPORTING CUSTOMERS WITH INTEGRITY          TECHNICAL COMPETENCE           QUALITY  PRODUCTS        SUPERIOR SERVICE          RESPONSIVE TO CUSTOMER NEED           BEST VALUE FOR YOUR INVESTMENT
  Info Request Complete Info Form
 
E-mail me information about products on this page:
BrochureProducts -> Vibration -> Condition Monitoring -> Two-Wire Transmitters  

TWO-WIRE VIBRATION TRANSMITTER

Two-wire vibration transmitters are 'loop-powered' devices that provide a continuous 4-20 ma signal proportion to the level of machine vibration calibrated in units of acceleration, velocity or displacement. These rugged, hermetically-sealed transmitters provide continuous machine condition signals for remote alarming, display or trending.  Two-wire vibration transmitters are first broken down into two catagories..... top exit electrical connection transmitters and side exit electrical connection transmitters.  While both styles offer equial measurement performance, these two configurations allow the customer to choose which style will best suit his installation requirements.

 

TOP EXIT Vibration Transmitters                                                                                                        (A=Acceleration   V=Velocity   D=Displacement)

                                                   
  PC420A* PC420V* Dual Output
(spec. for PC420A & V)
PC420V* PC420D
Cal (4-20ma): 0-5, 0-10 or 0-20 g's
Peak, RMS or True Peak
0-0.5, 0-1, 0-2, 0-3 or 0-5 ips
Peak, RMS or True Peak
“DA” = any std g’s 4-20ma AND dynamic 100mv/g
“DV” = any std ips 4-20ma AND dynamic 100mv/in/sec
1XRunning Speed Transmitter
0 - 1.0 ips only
Peak only

0 - 40 mils pk-pk

Loop Power: 10 to 30 VDC 10 to 30 VDC 10 to 30 VDC 10 to 30 VDC 10 to 30 VDC
Ceramic Sensor: shear shear shear shear shear
Freq. Resp. 3dB: 2.0 - 2.0 kHz 2.0 - 2.0 kHz 4-20ma Output: 2.0 – 2.0 kHz
Dynamic Signal Output: 2.0 – 2.5 kHz
3 - 40 Hz 4 - 2 kHz
Temp. Rating: -40° to 85°C -40° to 85°C -40° to 85°C -40° to 85°C -40° to 85°C
Housing: 316L SS, hermetically sealed 316L SS, hermetically sealed 316L SS, hermetically sealed 316L SS, hermetically sealed

316L SS,

hermetically sealed

Elect. Connection: 2-pin top ** 2-pin top ** 3-pin top *** 2-pin top ** 2-pin top **
Mounting: 1/4-28 NPT stud 1/4-28 NPT stud 1/4-28 NPT stud 1/4-28 NPT stud 1/4-28 NPT stud
  Brochure (84K PDF) Brochure (84K PDF) PC420A Dual Brochure (97K PDF)
PC420V Dual Brochure (97K PDF)
Brochure (43K PDF) Brochure (262 K PDF)
  * optional approvals: CSA Explosion Proof (Class I/II/III, Div. ½) - 1" NPT style with integral 36" cable
CSA Intrinsically Safe (Class I, Div. 1 when used with available barrier)

R6Q 2-socket boot connector

6QI   

** 6QI 2-socket boot connector with J9T2A 2 conductor shielded cable with Teflon jacket

*** 6GQI 3-scket boot connector (or with J9T3A 3 conductor shielded cable with Teflon jacket

 

SIDE EXIT Vibration Transmitters                                                                                             (A=Acceleration  V=Velocity)

                   
  PC421-V or A PC423-V or A

PC425-V or A

and Temperature

PC427-V or A
Cal. (4-20 ma):

0-5, 0-10, 0-20 g's

or

0-.5, 0-1, 0-2, 0-3, 0-5 ips

and select
Peak, RMS,True Peak

0-5, 0-10 or 0-20 g's

or

0-.5, 0-1, 0-2, 0-3 or 0-5 ips

and select

Peak, RMS,True Peak

Vibration = as per PC421


Temperature = 10 mv/ deg K

Vibration = as per PC421


Temperature = 10 mv/ deg K

Loop Power:

10 to 30 VDC

10 to 30 VDC

Vibration: 10 to 30 VDC

Temp.: 12 - 24V IEPE Type

Vibration: 10 to 30 VDC

Temp.: 12 - 24V IEPE Type

Ceramic Sensor: shear shear shear shear
Freq. Resp. ± 3dB:

 

4.0 - 2.0 kHz

 

4.0 - 2.0 kHz

4-20ma: 4.0 – 2.0 kHz


Temp.: 223 -  358 Deg K

     (-50 to 85 Deg C)

4-20ma: 4.0 – 2.0 kHz


Temp.: 223 -  358 Deg K

       (-50 to 85 Deg C)

Temperature Rating: -40° to 85°C -40° to 85°C -40° to 85°C -40° to 85°C
Housing: 316L SS, hermetically sealed 316L SS, hermetically sealed 316L SS, hermetically sealed 316L SS, hermetically sealed
Electrical Connection:

2-pin side**

or

3-pin if dynamic *** output opt'n selected

Integral Cable

PN J95 5-conductor shielded cable, 10' long

6-pin side ****

Integral Cable

PN J95 5-conductor shielded cable, 10' long

Mounting: 1/4-28 captive bolt 1/4-28 captive bolt 1/4-28 captive bolt 1/4-28 captive bolt
  PC421 Brochure PC423 Brochure PC425 Brochure PC427 Brochure
     

R6Q 2-socket boot connector

6QI     

CONNECTOR / CALBE RECOMMENDATION

** 6QI 2-socket boot connector with J9T2A 2cond. shielded cable with Teflon jacket

*** 66GQI 3-scket boot connector with J9T3A 3 cond. shielded cable with Teflon jacket

**** 19SLI 6-socket connector with J95 5-conductor shielded cable

   

 


Products | Company | Resources | Training | Rentals | New Products
Spectrum Instruments Ltd., 126 West Ridge Drive, Ottawa, ON K2S 2H1
Ph: 1-800-778-3428   Fax: 1-866-556-0096   Outside Canada 1-613-831-0007   E-mail:
Copyright © 2004 Spectrum Instruments Ltd.
Web Development by: FOG Designs

updated: April 28, 2008